93 research outputs found

    Prospective comparison of novel dark blood late gadolinium enhancement with conventional bright blood imaging for the detection of scar

    Get PDF
    BACKGROUND: Conventional bright blood late gadolinium enhancement (bright blood LGE) imaging is a routine cardiovascular magnetic resonance (CMR) technique offering excellent contrast between areas of LGE and normal myocardium. However, contrast between LGE and blood is frequently poor. Dark blood LGE (DB LGE) employs an inversion recovery T2 preparation to suppress the blood pool, thereby increasing the contrast between the endocardium and blood. The objective of this study is to compare the diagnostic utility of a novel DB phase sensitive inversion recovery (PSIR) LGE CMR sequence to standard bright blood PSIR LGE. METHODS: One hundred seventy-two patients referred for clinical CMR were scanned. A full left ventricle short axis stack was performed using both techniques, varying which was performed first in a 1:1 ratio. Two experienced observers analyzed all bright blood LGE and DB LGE stacks, which were randomized and anonymized. A scoring system was devised to quantify the presence and extent of gadolinium enhancement and the confidence with which the diagnosis could be made. RESULTS: A total of 2752 LV segments were analyzed. There was very good inter-observer correlation for quantifying LGE. DB LGE analysis found 41.5% more segments that exhibited hyperenhancement in comparison to bright blood LGE (248/2752 segments (9.0%) positive for LGE with bright blood; 351/2752 segments (12.8%) positive for LGE with DB; p < 0.05). DB LGE also allowed observers to be more confident when diagnosing LGE (bright blood LGE high confidence in 154/248 regions (62.1%); DB LGE in 275/324 (84.9%) regions (p < 0.05)). Eighteen patients with no bright blood LGE were found to have had DB LGE, 15 of whom had no known history of myocardial infarction. CONCLUSIONS: DB LGE significantly increases LGE detection compared to standard bright blood LGE. It also increases observer confidence, particularly for subendocardial LGE, which may have important clinical implications

    Functional relevance of coronary artery disease by cardiac magnetic resonance and cardiac computed tomography : myocardial perfusion and fractional flow reserve

    Get PDF
    Coronary artery disease (CAD) is one of the leading causes of morbidity and mortality and it is responsible for an increasing resource burden. The identification of patients at high risk for adverse events is crucial to select those who will receive the greatest benefit from revascularization. To this aim, several non-invasive functional imaging modalities are usually used as gatekeeper to invasive coronary angiography, but the diagnostic yield of elective invasive coronary angiography remains unfortunately low. Stress myocardial perfusion imaging by cardiac magnetic resonance (stress-CMR) has emerged as an accurate technique for diagnosis and prognostic stratification of the patients with known or suspected CAD thanks to high spatial and temporal resolution, absence of ionizing radiation, and the multiparametric value including the assessment of cardiac anatomy, function, and viability. On the other side, cardiac computed tomography (CCT) has emerged as unique technique providing coronary arteries anatomy and more recently, due to the introduction of stress-CCT and noninvasive fractional flow reserve (FFR-CT), functional relevance of CAD in a single shot scan. The current review evaluates the technical aspects and clinical experience of stress-CMR and CCT in the evaluation of functional relevance of CAD discussing the strength and weakness of each approach

    Performance of a deep learning algorithm for the evaluation of CAD-RADS classification with CCTA

    Get PDF
    Background and aims: Artificial intelligence (AI) is increasing its role in diagnosis of patients with suspicious coronary artery disease. The aim of this manuscript is to develop a deep convolutional neural network (CNN) to classify coronary computed tomography angiography (CCTA) in the correct Coronary Artery Disease Reporting and Data System (CAD-RADS) category. Methods: Two hundred eighty eight patients who underwent clinically indicated CCTA were included in this single-center retrospective study. The CCTAs were stratified by CAD-RADS scores by expert readers and considered as reference standard. A deep CNN was designed and tested on the CCTA dataset and compared to on-site reading. The deep CNN analyzed the diagnostic accuracy of the following three Models based on CAD-RADS classification: Model A (CAD-RADS 0 vs CAD-RADS 1–2 vs CAD-RADS 3,4,5), Model 1 (CAD-RADS 0 vs CAD-RADS&gt;0), Model 2 (CAD-RADS 0–2 vs CAD-RADS 3–5). Time of analysis for both physicians and CNN were recorded. Results: Model A showed a sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 47%, 74%, 77%, 46% and 60%, respectively. Model 1 showed a sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 66%, 91%, 92%, 63%, 86%, respectively. Conversely, Model 2 demonstrated the following sensitivity, specificity, negative predictive value, positive predictive value and accuracy: 82%, 58%, 74%, 69%, 71%, respectively. Time of analysis was significantly lower using CNN as compared to on-site reading (530.5 ± 179.1 vs 104.3 ± 1.4 sec, p=0.01) Conclusions: Deep CNN yielded accurate automated classification of patients with CAD-RADS

    Multiparametric Echocardiography Scores for the Diagnosis of Cardiac Amyloidosis

    Get PDF
    OBJECTIVES: This study aimed to investigate the accuracy of a broad range of echocardiographic variables to develop multiparametric scores to diagnose CA in patients with proven light chain (AL) amyloidosis or those with increased heart wall thickness who had amyloid was suspected. We also aimed to further characterize the structural and functional changes associated with amyloid infiltration. BACKGROUND: Cardiac amyloidosis (CA) is a serious but increasingly treatable cause of heart failure. Diagnosis is challenging and frequently unclear at echocardiography, which remains the most often used imaging tool. METHODS: We studied 1,187 consecutive patients evaluated at 3 referral centers for CA and analyzed morphological, functional, and strain-derived echocardiogram parameters with the aim of developing a score-based diagnostic algorithm. Cardiac amyloid burden was quantified by using extracellular volume measurements at cardiac magnetic resonance. RESULTS: A total of 332 patients were diagnosed with AL amyloidosis and 339 patients with transthyretin CA. Concentric remodeling and strain-derived parameters displayed the best diagnostic performance. A multivariable logistic regression model incorporating relative wall thickness, E wave/e' wave ratio, longitudinal strain, and tricuspid annular plane systolic excursion had the greatest diagnostic performance in AL amyloidosis (area under the curve: 0.90; 95% confidence interval: 0.87 to 0.92), whereas the addition of septal apical-to-base ratio yielded the best diagnostic accuracy in the increased heart wall thickness group (area under the curve: 0.80; 95% confidence interval: 0.85 to 0.90). CONCLUSIONS: Specific functional and structural parameters characterize different burdens of CA deposition with different diagnostic performances and enable the definition of 2 scores that are sensitive and specific tools with which diagnose or exclude CA

    CT angiography prior to TAVI procedure using third-generation scanner with wide volume coverage : feasibility, renal safety and diagnostic accuracy for coronary tree

    Get PDF
    OBJECTIVE: To evaluate feasibility, image quality and accuracy of a reduced contrast volume protocol for pre-procedural CT imaging in transcatheter aortic valve implantation (TAVI) using a third generation wide array CT scanner. METHODS: 115 consecutive patients (51F, mean age 82.5 \ub1 6.2 y, mean BMI 26.7 \ub1 3.6) referred for TAVI were examined with wide-array CT scanner with a combined scan protocol and a total amount of 50 ml contrast agent. A 4-point visual scale (4-1) was used to assess image quality . Contrast attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the level of the aortic root, ascending/descending aorta, subrenal aorta and at the level of right and left common femoral arteries. Coronary tree was assessed and compared with invasive coronary angiography (ICA). Aortic annulus measurements were compared with final procedural results. Patients creatinine was monitored at the baseline and 72 h after procedure. RESULTS: Median quality score value was >3. Mean CNR at the level of the aortic root, ascending/descending aorta, subrenal aorta and at the level of right and left common femoral arteries were 14.8 \ub1 2.3, 15.7 \ub1 1.7, 14.9 \ub1 3.1, 15.8 \ub1 4.7, 20.3 \ub1 9.9, 20.8 \ub1 6.9 respectively. Only 1 patient had moderate paravalvular regurgitation. In comparison with ICA for coronary assessment CTA showed in a segment based analysis sensitivity, specificity, negative predictive value, positive predictive value and accuracy of 97, 85, 99,62 and 88% respectively. Mean creatinine before CT and 72 h after procedure were 1.21 \ub1 0.52 and1.22 \ub1 0.49 mg dl-1. Mean DLP was 442.4 \ub1 21.2 mGy/cm. CONCLUSION: CT with low contrast volume is feasible and clinically useful, allowing precise pre-procedural TAVI planning with accurate assessment of coronary tree. Advances in knowledge: third generation CT scanner with whole heart coverage allows examinations for assessment of aorta and coronary arteries in TAVI planning using low dose of contrast medium maintaining good quality and high diagnostic accuracy

    Age- and sex-related features of atherosclerosis from coronary computed tomography angiography in patients prior to acute coronary syndrome: results from the ICONIC study

    Get PDF
    Aims Although there is increasing evidence supporting coronary atherosclerosis evaluation by coronary computed tomography angiography (CCTA), no data are available on age and sex differences for quantitative plaque features. The aim of this study was to investigate sex and age differences in both qualitative and quantitative atherosclerotic features from CCTA prior to acute coronary syndrome (ACS).Methods and results Within the ICONIC study, in which 234 patients with subsequent ACS were propensity matched 1:1 with 234 non-event controls, our current subanalysis included only the ACS cases. Both qualitative and quantitative advance plaque analysis by CCTA were performed by a core laboratory. In 129 cases, culprit lesions identified by invasive coronary angiography at the time of ACS were co-registered to baseline CCTA precursor lesions. The study population was then divided into subgroups according to sex and age (<65 vs. = 65 years old) for analysis. Older patients had higher total plaque volume than younger patients. Within specific subtypes of plaque volume, however, only calcified plaque volume was higher in older patients (135.9 +/- 163.7 vs. 63.8 +/- 94.2 mm(3), P < 0.0001, respectively). Although no sex-related differences were recorded for calcified plaque volume, females had lower fibrous and fibrofatty plaque volume than males (Fibrofatty volume 29.6 +/- 44.1 vs. 75.3 +/- 98.6 mm(3), P = 0.0001, respectively). No sex-related differences in the prevalence of qualitative high-risk plaque features were found, even after separate analyses considering age were performed.Conclusion Our data underline the importance of age- and sex-related differences in coronary atherosclerosis presentation, which should be considered during CCTA-based atherosclerosis quantification.Cardiolog

    Coronary atherosclerosis assessment by coronary CT angiography in asymptomatic diabetic population: A critical systematic review of the literature and future perspectives

    No full text
    The prognostic impact of diabetes mellitus (DM) on cardiovascular outcomes is well known. As a consequence of previous studies showing the high incidence of coronary artery disease (CAD) in diabetic patients and the relatively poor outcome compared to nondiabetic populations, DM is considered as CAD equivalent which means that diabetic patients are labeled as asymptomatic individuals at high cardiovascular risk. Lessons learned fromthe analysis of prognostic studies over the past decade have challenged this dogma and now support the idea that diabetic population is not uniformly distributed in the highest risk box. Detecting CAD in asymptomatic high risk individuals is controversial and, what ismore, in patients with diabetes is challenging, and that is why the reliability of traditional cardiac stress tests for detectingmyocardial ischemia is limited. Cardiac computed tomography angiography (CCTA) represents an emerging noninvasive technique able to explore the atherosclerotic involvement of the coronary arteries and, thus, to distinguish different risk categories tailoring this evaluation on each patient. The aim of the review is to provide a wide overview on the clinical meaning of CCTA in this field and to integrate the anatomical information with a reliable therapeutic approach

    Overall evaluability of low dose protocol for computed tomography angiography of thoracic aorta using 80kV and iterative reconstruction algorithm using different concentration contrast media

    No full text
    Introduction: Multidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. Methods: Two-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100\uc2\ua0Kvp tube voltage), Group C (Iomeprol 400 and 80\uc2\ua0Kvp tube voltage) and Group D (Iomeprol 400 and 100\uc2\ua0Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. Results: No significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80\uc2\ua0kV versus groups using 100\uc2\ua0kV but without differences in terms of image quality. ED was significantly lower in groups with 80\uc2\ua0kV. Conclusions: Multidetector Computed Tomography Angiography protocols using 80\uc2\ua0kV and low concentration contrast media are feasible without need of tailored injection protocols
    corecore